The Bio-Hazard Sterilizer
Process
The medical waste sterilizers operate with the technology of a high vacuum steam environment; with steam as the sterilization agent, operating at a pressure of up to 33PSI (2.3 bars) and a temperature of up to 279°F (137°C). Due to the unique design and special construction of the autoclave, together with the regulations requiring a minimum sterilization of 30 minutes, the sterilization cycle is relatively short, the entire cycle is no more than about 50 minutes.
Construction
-
Pressure Vessel and door
Constructed of heavy-duty 316L-grade stainless steel, both single and double door models are available.
-
Jacket
Constructed of heavy-duty 304L grade stainless steel.
-
Piping and fittings
Stainless steel and brass. The valves are ball piston type, self cleaning and pneumatically operated.
-
Mounting
Can be supplied in one of the following mounting alternatives: Built-in, wall mounted, Free-standing and Pit-mounted (floor loading).
-
Loading
The chamber is supplied with two rails for easy loading. A variety of stainless steel loading equipment is available for your selection.
Doors
The sterilizers can be supplied with one or two doors. The door/s can be fully automatic vertically sliding, horizontally sliding, or hinged with automatic locking. All door types are equipped with special safety device features that prevent the doors from opening while in operation.
Automatic Control Unit
The Medical Waste (BH) sterilizer control system is based on “state-of-the-art” microcomputer technology, guaranteeing high reliability and safe operation. Intervention is unnecessary after selecting the parameters and pressing the start button. The main cycle phases and the machine’s actual parameters are displayed on the LCD panel during the cycle progress. The main physical parameters of the process, i.e.temperature, pressure, time and jacket pressure are controlled and displayed. The control system is easy to use and programmable.Calibration of the system can be per formed digitally from the control panel or through a computer communication port via a PC.
Documentation
For a clear and concise documentation of cycle process, the control unit is provided with a 24 character per line printer, which is connected to the microprocessor. In case of an uncompleted cycle, the printout will indicate the cycle failure and the cause of the failure. An additional graphic printer is available,RS485/RS232 PC and Advanced PC Windows-based software for monitoring, logging and control is also available. A circular or trace strip chart temperature and pressure recorder can be supplied on request.
Loading Cart and Carriage
Tuttnauer offers a complete product range of high-grade Stainless steel (316L)Loading Equipment.
Standarts: Loading cart and transfer carriage.
Optional: Highly automated load in and/or unloading for your sterilizers.
The loading equipment is ergonomically designed for safe, simple, easy to use,
material handling in your facility.